• HI12KDL-855.png
  • HI12KDL-465.png
  • HI12KDL-889.png
Hybrid Inverters

HI-5~12K-DL

  • 5~12kW
  • Split Phase
  • Low Voltage

Technical Parameters

Inhenergy HI-5~12K-DL is a model specially developed for North America. This is inhenergy’s first split-phase inverter, which is perfectly matched with low-voltage batteries and is suitable for households and small commercial scenarios.

  • fuyong2.png

    Core Value
    Future proof battery ready
    Low initial investment

  • fuyong1.png

    High Yields
    DC/AC ratio up to 1.5
    Max. efficiency 98%
    Dual MPP trackers

  • gongsijieshaoyoushishujuTop3.png

    Safety and Reliability
    Type II SPD on DC side
    Support export limitation

  • rentou.png

    User Friendly
    Compact design for one person installation

  • 10ms-129.png

    Leading Functions
    UPS function, 10ms transition
    Smart Meter Integrated

  • dianchi.png

    System Flexibility
    Support lithium and lead-acid battery

Technical Data
Model NumberHI-5K-DLHI-6K-DLHI-8K-DLHI-10K -DL

HI-12K-DL

PV String Input Data




Max. DC input power7.5kW9kW12kW15kW18kW
Max. DC input voltage

550V

Nominal input voltage

360V

MPPT working voltage range

90V-550V

Number of independent MPPT/strings per MPPT2/12/14/14/14/1
MPPT max. current20A*220A*220A*420A*420A*4
Start-up voltage

100V

AC Output/Input Data (On-grid)




Nominal output apparent power5kW6kW8kW10kW12kW
Max. output apparent power5.5kVA6.6kVA8.8kVA11kVA13.2kVA
Nominal output voltage

120V/240V(Split phase), 208V(2/3phase), 230V(Single phase)

Nominal ouput freqency

60HZ/50HZ±0.2%

Rated output current20.8/21.7A25/26A33/34.7A41.6/43.4A50/52A
Max. output current26A32A42A53A60A
Power factor

-0.8~+0.8(adjustable)

THDi

<3%(Nominal Output)

Grid system pattern

Split phase,2/3 phase, Single phase

Max.apparent power from utility grid11kVA12kVA16kVA20kVA24kVA
Max.AC current from utility grid52A64A84A106A120A
Back-up Output Data (UPS)




Nominal output apparent power5kVA6kVA8kVA10kVA12kVA
Max. output apparent power5.5kVA6.6kVA8.8kVA11kVA13.2kVA
Nominal output voltage

120V,208V,220V,240V

Nominal ouput frequency

60Hz/50Hz±0.2%

Output THDV

<3%

Automatic switch time

<10ms

Battery Input Data




Battery type

Li-Ion/Lead-acid

Battery voltage range

40V-60V

Max. charging/discharging current100A120A160A200A240A
Charging strategy for Li-Ion battery

Self-adaption to BMS

Charging strategy for Lead-acid battery

Three-stage

Efficiency




Max. effificiency

98%

Europe effificiency

97 . 5%

Max. battery to load effificiency

98%

Protection




Anti islanding protection

Yes

Insulation impedance protection

Yes

RCD detection

Yes

PV reverse polarity protection

Yes

Output over voltage protection

Yes

Output over current protection

Yes

General Data




Dimensions(L/W/H)in mm

425/280/660

Weight

35kg

Operation temperature range

-25℃~+60℃

Heat dissipation mode

Smart cooling

IP Class

IP 65

Maximum altitude

3000m

Self-Consumption night

<3w

Topology

Transformerless

Features




LCD display

Yes

Communication interface

WiFi/4G/USB/CAN/RS485

Standards

UL 1741,CSA C22.2,UL 1699B, UL 1741SB,IEEE1547:2018,RULE21,FCC Part 15 Class B